Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Atmospheric Technician: Difference between revisions

From Delta-V Wiki
mNo edit summary
 
m (Fixed the redirects, what was Waste, Distro and Nuclear Operative doing there??? Also it was missing a dot D:)
 
(9 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Needs revision|reason=Move Gas related info to [[Gases]] and how to set up atmospheric to [[Atmospheric Science]]. Add how to deal with pressure, preventing/dealing with gas flood, etc.}}
{{Job_Header
{{Job_Header
|department=ENGINEERING
|department=ENGINEERING
Line 7: Line 6:
|title=Atmospheric Technician
|title=Atmospheric Technician
|difficulty=Medium to Hard
|difficulty=Medium to Hard
|requirements=Whitelisted
|requirements=10 hours in [[Station Engineer|Engineering]]
|access=Maintenance, Engineering, External, Atmospherics
|access=Maintenance, Engineering, External, Atmospherics
|extendedaccess=None
|extendedaccess=None
Line 15: Line 14:
|guides=[[Atmospheric Science]], [[Pipes and vents]], [[Gases]], [[Setting up the mix chamber]]  
|guides=[[Atmospheric Science]], [[Pipes and vents]], [[Gases]], [[Setting up the mix chamber]]  
}}
}}
__NOTOC__ <!-- Removes table of contents -->
As an atmospheric technician, your primary job is to maintain a safe and breathable atmosphere inside the station. As a member of the engineering department, you may also be expected to double as a [[Station Engineer]] <s>if they don't know what they're doing</s> in exceptional circumstances.
As an atmospheric technician, your primary job is to maintain a safe and breathable atmosphere inside the station. As a member of the engineering department, you may also be expected to double as a [[Station Engineer]] <s>if they don't know what they're doing</s> in exceptional circumstances.


Line 21: Line 19:


* Air escaping into space due to intentional or unintentional removal of walls or floor tiles (''spacing'')
* Air escaping into space due to intentional or unintentional removal of walls or floor tiles (''spacing'')
* Buildup of unpleasant or outright hazardous [[#Gases|gases]] such as miasma or plasma
* Buildup of unpleasant or outright hazardous [[#Gases|gases]] such as ammonia or plasma


Atmospheric technicians are essential to keeping the station alive and breathing, and consequently are ineligible to be [[Traitor]].
Atmospheric technicians are essential to keeping the station alive and breathing, and consequently are ineligible to be [[Traitor]].


Your supervisor is the [[Chief Engineer]].


==Quick-Start==
==Quick-Start==
# Grab [[#Equipment|equipment]] from your atmospheric technician locker. You should grab at least a hardsuit or fire suit and helmet, a gas mask and gas tank, a gas analyzer, and a holofan projector. Consider grabbing inflatable walls, inflatable doors, steel sheets, and metal rods to be ready to fix spacing.
# Grab [[#Equipment|equipment]] from your atmospheric technician locker. You should grab at least a hardsuit or fire suit and helmet, a gas mask and gas tank, a gas analyzer, and a holofan projector. Consider grabbing inflatable walls, inflatable doors, steel sheets, and metal rods to be ready to fix spacing.
# Find the [[#Distro|distro]] pipe and inspect its pressure and temperature using your [[#Equipment|gas analyzer]]. If the pressure is zero and shows no sign of rising, take corrective action.
# Find the distro pipe and inspect its pressure and temperature using your [[#Equipment|gas analyzer]]. If the pressure is zero and shows no sign of rising, take corrective action.
# (''optional'') Set filters to recover gases from the [[#Waste|waste]] pipe. Because [[Pipes_and_vents#Gas_Miner|gas miners]] are available on most stations, this step is not very important. And, unless [[Pipes_and_vents#Air_Scrubber|scrubbers]] are set to siphoning, there will only be waste gases in the waste pipe.
# (''optional'') Set filters to recover gases from the waste pipe. Because [[Pipes_and_vents#Gas_Miner|gas miners]] are available on most stations, this step is not very important. And, unless [[Pipes_and_vents#Air_Scrubber|scrubbers]] are set to siphoning, there will only be waste gases in the waste pipe.
# Deliver [[#Equipment|portable scrubbers]] to locations that expect miasma build up. This is usually the [[Medical#Cloning_and_Morgue|cloning room or morgue in the medical bay]].
# Deliver [[#Equipment|portable scrubbers]] to locations that expect miasma build up. This is usually the [[Medical#Cloning_and_Morgue|cloning room or morgue in the medical bay]].
# Monitor the station's radio or patrol the station yourself for spacing or other atmospheric issues. Fix issues if they arise.
# Monitor the station's radio or patrol the station yourself for spacing or other atmospheric issues. Fix issues if they arise.
# Make sure that [[Assistant|suspicious]] [[Nuclear_Operative|people]] are not sabotaging [[#Atmosia|your department]].
# Make sure that [[Antagonist|suspicious people]] are not sabotaging your department.
 
==Gases==
The bread and butter of an atmospheric technician. Gases can be found:
 
# In the air around you, so long as there are four walls and a floor enclosing it and preventing it from escaping into space,
# In containers like portable gas tanks and large gas cylinders, and
# In pipes and other atmospheric devices.
 
{| class="wikitable sortable"
|+ Gases in SS14
|-
! Gas !! Description !! Specific Heat Capacity !! Molar Mass (g/mol)
|-
| Oxygen<br> [[File:Oxygen gas.png]] || Colorless, reactive gas that humans need to breathe to stay alive. Key oxidizing agent in most combustion reactions. || 20 || 32
|-
| Nitrogen<br> [[File:Nitrogen gas.png]] || Colorless, odorless, inert gas. Somehow, slimes and voxes breathe this. || 30 || 28
|-
| Carbon Dioxide<br> [[File:Carbon dioxide.png]]|| Colorless, odorless, relatively inert gas. Exhaled by creatures that breathe oxygen. Toxic in high enough quantities. The reason why atmospheric technicians are employed. || 30 || 44
|-
| Plasma<br> [[File:Plasma gas.png]] || Purple, putrid, highly-combustible, and toxic gas. Combusts in the presence of oxygen. Unfortunately, it is also vitally important to industrial and scientific activities aboard Nanotrasen stations.|| 200 || 120
|-
| Tritium<br> [[File:Tritium gas.png]] || Green, highly-combustible, and radioactive. Combusts in the presence of oxygen. It is not mined, and its production is a highly-guarded trade secret. || 10 || 6
|-
| Water Vapor<br> [[File:Water vapor.png]] || Water in gaseous form. Due to the unique environment of space, does not condense into liquid water. Harmful to slime people. || 40 || 18
|-
| Miasma || Brownish, foul-smelling gas. Breeds disease, toxic, and harmful in sufficiently large concentrations. A by-product of nasty biological processes, including rotting bodies. || 20 || 44
|-
| Nitrous Oxide || Bluish gas. Otherwise known as "laughing" or "sleepy" gas, it acts as a sedative to non-slimes and is toxic in very high concentrations. Unfortunately, this stuff is exhaled by slimes. || 40 || 44
|-
| Frezon || Blue-greenish gas. Used as an industrial coolant. Used recreationally by some for its euphoric effects, before their lungs freeze out. Proposition 65 Warning. || 600 || 50
|}
 
About 79% nitrogen to 21% oxygen is the standard air mix.  


==Equipment==
==Equipment==
Line 80: Line 44:
| [[File:Gas Analyzer.png|64px]] || Gas Analyzer || Use this to analyze the composition of gases in the air around you, or to measure the temperature and pressure of gases inside pipes.
| [[File:Gas Analyzer.png|64px]] || Gas Analyzer || Use this to analyze the composition of gases in the air around you, or to measure the temperature and pressure of gases inside pipes.
|-
|-
| [[File:Portable Scrubber.png|64px]] || Portable Scrubber || Can be wrenched down to scrub waste gases to an internal tank. Useful for cleaning up a miasma problem. Must be emptied once full.
| [[File:Portable Scrubber.png|64px]] || Portable Scrubber || Can be wrenched down to scrub waste gases to an internal tank. Useful for quickly containing gas leaks. Must be emptied once full.
|-
|-
| [[File:Holofan Projector.png|64px]] || Holofan Projector || [[File:Holofan.png|thumb|right|A holofan projection]] Creates a holographic firelock (''holofan'') that blocks gas flow but allows objects to move through them. Holofans last for three minutes before despawning. Extremely useful when repairing a hull breach, since they will safely block the flow of station atmosphere while still giving access to move around freely to work. Stores a total of six charges before the internal [[Power cell]] runs out of power.
| [[File:Holofan Projector.png|64px]] || Holofan Projector || [[File:Holofan.png|thumb|right|A holofan projection]] Creates a holographic firelock (''holofan'') that blocks gas flow but allows objects to move through them. Holofans last for three minutes before despawning. Extremely useful when repairing a hull breach, since they will safely block the flow of station atmosphere while still giving access to move around freely to work. Stores a total of six charges before the internal [[Power cell]] runs out of power.
Line 86: Line 50:


==Atmosia==
==Atmosia==
''Main article: [[Atmospheric_Science|Atmospheric Science]]''
Atmospherics, sometimes referred to as Atmosia, is where most of the station's air handling machinery is located. Each station has a different atmospherics layout. While seasoned atmospheric technicians may have atmospheric layouts memorized, frequent <s>useless station remodeling</s> station engineering changes mean that it is more important to be able to quickly understand the layout of the station that you're currently working on.
Atmospherics, sometimes referred to as Atmosia, is where most of the station's air handling machinery is located. Each station has a different atmospherics layout. While seasoned atmospheric technicians may have atmospheric layouts memorized, frequent <s>useless station remodeling</s> station engineering changes mean that it is more important to be able to quickly understand the layout of the station that you're currently working on.


===Atmos Annotated===
==Gases==
A typical atmospherics layout is shown below:
''Main article: [[Gases]]''
 
[[File:Atmosia Annotated.png]]
 
# Nitrogen holding chamber with (maybe) a nitrogen gas miner
# Oxygen holding chamber with (maybe) a oxygen gas miner
# Pump for moving nitrogen to the mixer
# Pump for moving oxygen to the mixer
# Mixer to mix nitrogen and oxygen in an appropriate ratio for the station
# Volume pump to move mixer output to the station's main distro pipe
# Main distro pipe
# Valve to shut off freezer
# Freezer to reduce air temperature in distro
# Valve to shut off heater
# Heater to increase air temperature in distro
# Main waste pipe
# Volume pump to move air into the filter banks
# Bank of filters to separate different types of gases from the waste pipe
 
===Holding Chambers===
[[File:Atmos holding chambers.png|thumb|Gas holding chambers]]
 
Holding chambers store a supply of gas for you to pump into the station when needed. Some stations come with gas miners that produce an unlimited supply of the mined gas. Walls and windows prevent gas from escaping to space; if the holding chambers are broken, then the gas inside will be lost.
 
Holding chambers may be labeled with the [[#Gases|type of gas]] that they are designed to store.
 
Use [[Pipes and vents#Pumps|pumps]] to move gases in and out of holding chambers.
 
===Distro===
The station's main air distribution loop, also known as ''distro'', supplies the air vents that pump air into the station. It is usually colored dark blue to make it easily identifiable.
 
Air vents will pump air from distro into the station as long as the pressure inside distro is positive. Increasing the pressure inside distro allows the air vent pumps to move air faster. Contrary to popular belief, the pressure inside '''does not''' set the pressure of air coming out of the actively pumped air vents that start connected to distro.
 
Check the pressure of distro at round start and periodically throughout the shift. Low or slowly rising distro pressure at round start is a sign of <s>shoddy station quality</s> design flaws causing low flow rates into distro. Low distro pressure in the middle of the round may be indicative of spacing on the station.
 
====Setting Up Distro====
Setting up distro means to configure the layout to more effectively pump gases into distro. Specific steps to do so vary from station to station. Here is an example of setting up distro for the [[#Atmos Annotated|example above]]:
 
# Remove (6) and replace it with a straight pipe segment. Pumps reduce gas flow rate, and when spacing occurs, (6) is typically a bottleneck when re-pressurizing the station.
# Set (5) to output 310 kPa. The pressure in the distro pipe influences how quickly air vents can move air from distro into the station. Setting this too low reduces the flow rate, but setting this too high could be dangerous if a [[Traitor]] replaces an air vent with a passive vent.
# Increase output pressure of (3) and (4) to their maximum settings.
 
===Waste===
Waste, or the waste loop, is usually marked with red pipes and is responsible for removing waste gas around the station via scrubbers. These pipes start and end in atmospherics and are looped around the entire station. The main purpose of the waste loop is the ensure that harmful gases get removed from the station's atmosphere. Scrubbers will remove gas from the hallways and return it to Atmospherics where it will then be separated by gas filters into various holding chambers. Harmful gases will be deposited into their assigned chambers and the breathable air will once again make its way back to Distro and into the station to continue the cycle.
 
===Mix Chamber===
 
[[File:Mix chamber in use.png|thumb|A mix chamber in use]]
 
The mix chamber is an empty holding area with its own separate loop of pipes and pumps in atmospherics. The mix loop is generally marked with brown pipes and the holding chamber can usually be found close to the external hull, separated from the station by reinforced walls and windows. There will be an emergency button nearby to vent the chamber to space if you need to dump your mix in case an accident arises, or you just wish to reset the chamber for a new mix. The mix chamber is here for you to experiment with different mixes, ratios, temperatures, and pressures while combining gases.
 
On most stations the Mix chamber will loop around to either the [[Supermatter]] chamber, to the distro loop, or back to the waste loop. It is generally a good practice to have your mix loop flow back into the waste loop to recycle any unspent gases. You should '''NEVER''' have the mix loop flow into distro unless you have a [[Traitor|very good reason.]] Most savvy Atmospherics Technicians physically disconnect the mix loop from distro at round start to prevent an easy sabotage target or accident from occurring later in the round.
 
See the guide to [[Gases]] if you are interested to learn how different gases interact with each other at different temperatures and pressures.
 
See the guide to [[Setting up the mix chamber]] if you want to learn how to properly and safely use the mix chamber.


==Pipes and Machinery==
==Pipes and Machinery==
Line 167: Line 78:
*Large hallway = more moles/higher temperatures needed to notice pressure change.
*Large hallway = more moles/higher temperatures needed to notice pressure change.
*Small hallway = less moles/higher temperatures needed to notice pressure change.
*Small hallway = less moles/higher temperatures needed to notice pressure change.
==Air Alarms==
Air Alarms can be found all over the station in form of panels. They connect and manage active vents, scrubbers, air sensors and firelocks together. They have 3 possible states: Normal, Warning and Alarm. Warning indicates possible build-up of dangerous gases or other issues with the atmosphere that aren't directly lethal. The Alarm state it will close all firelocks connected to that panel, indicating a possibly lethal threat, like a spacing.
At the bottom of the panel there is a mode selector. You can select between:
* Filtering - Normal filtering, removes all gases except Nitrogen and Oxygen.
* Filtering (wide) - Enables WideNet which also filters tiles adjacent to a scrubber.
* Fill - Turns off the scrubbers and fills the room through the vents.
* Panic - Sucks out all gases and turns off the vents.
You can view the atmosphere composition on the tile a sensor is located by using the Sensors tab, which gives you detailed insights about the gases, pressure and temperature.
==Dealing with gas leaks==
Gas leaks are a random even that occurs on the station. They can be usually quickly located by reports on the radio and firelocks going off. Most gases aren't directly harmful and are filtered off by the scrubbers network, but Tritium, Plasma or Frezon need to be quickly removed using Portable Scrubbers, usually found in the Atmos area of the Engineering department.
The most effective way of containing extreme pressures and temperatures (like these caused by plasma fires) is spacing the room, which can be done using an RCD or a fire axe.


==Space wind==
==Space wind==
Explosive decompression, or ''space wind,'' is caused when a sudden low pressure or depressurization zone occurs and all the atmosphere flows from high pressure to low pressure. Space wind often happens due to a sudden hull breach or when the clown opens the external airlock. All personnel and lose objects in the area will be flung toward the low pressure area as if a gust of wind blows you towards the breach site, thus the name 'Space Wind' is dubbed.
Explosive decompression, or ''space wind,'' is caused when a sudden low pressure or depressurization zone occurs and all the atmosphere flows from high pressure to low pressure. Space wind often happens due to a sudden hull breach or when the clown opens the external airlock. All personnel and lose objects in the area will be flung toward the low pressure area as if a gust of wind blows you towards the breach site, thus the name 'Space Wind' is dubbed.


Space wind is very deadly to any crew member not wearing hardsuits with internals. Space wind will often suck you far away from safety and toward the breach site. The damage you take from slamming into objects(and objects slamming into you) along with depressurization, lack of oxygen, and freezing temperatures will often quickly kill any unsuspecting crewmember who gets caught.
Space wind is very deadly to any crew member not wearing hardsuits with internals. Space wind will often suck you far away from safety and toward the breach site. The damage you take from slamming into objects (and objects slamming into you) along with depressurization, lack of oxygen, and freezing temperatures will often quickly kill any unsuspecting crewmember who gets caught.
 
'''Space wind was disabled on 5/9/2022 until it is fixed or there is a better alternative. You will no longer be pushed around by explosive decompression or airflows.'''


==Useful trivia and tricks==
==Useful trivia and tricks==
*Always be prepared to fix a breach. Carry your Atmospherics hardsuit or firesuit with you so you can survive long enough to fix any breach at a moments notice.
*Always be prepared to fix a breach. Carry your Atmospherics hardsuit or firesuit with you so you can survive long enough to fix any breach at a moments notice.
*The Atmospherics firesuit is space proof and functions like a hardsuit. Just make sure you wear the helmet with it or else it wont give you any protection.
*The Atmospherics firesuit is space proof and functions like a hardsuit. Just make sure you wear the helmet with it or else it wont give you any protection.
*The standard air mix is about 21% oxygen and 79% nitrogen @ 101.7 kPa at 293.2K (20°C).
*The standard air mix is 21% oxygen and 79% nitrogen @ 101.325 kPa at 293.15K (20°C).
*A quick and dirty way to vent high pressure or unwanted gases is to expose the area to open space. Breach a wall or open an airlock to quickly suck out all the atmosphere. Just be sure you have the area sealed off and no crewmembers get caught in the depressurization zone!
*A quick and dirty way to vent high pressure or unwanted gases is to expose the area to open space. Breach a wall or open an airlock to quickly suck out all the atmosphere. Just be sure you have the area sealed off and no crewmembers get caught in the depressurization zone!
*Overpressurization can be just as harmful as depressurization!
*Overpressurization can be just as harmful as depressurization!
*A pressurized pipe will violently decompress if unwrenched!  
*A pressurized pipe will violently decompress if unwrenched!  
*If you want to check the pressure and temperature of a pipe, hold your gas analyzer in hand, shift left-click on the pipe, and click on the magnifying glass in pop-up window.
*If you want to check the pressure and temperature of a pipe, hold your gas analyzer in hand and left-click on the pipe.
*Make sure that the distro loop never connects to anything else like the mix or waste loop. unless you want to flood the station with superheated plasma and risk getting an angry admin message.
*Make sure that the distro loop never connects to anything else like the mix or waste loop. unless you want to flood the station with superheated plasma and risk getting an angry admin message.


{{Jobs Menu}}
{{Jobs Menu}}
[[Category:Jobs]]
[[Category:Jobs]]

Latest revision as of 00:32, 28 January 2024

ENGINEERING STAFF

Atmospheric Technician
Difficulty: Medium to Hard
Requirements: 10 hours in Engineering
Access: Maintenance, Engineering, External, Atmospherics
Extended Access: None
Supervisors: Chief Engineer
Subordinates: None
Duties: Restore breathable atmosphere to depressurized areas. Ensure the station's air remains at liveable conditions. Get bored and create tritium.
Guides: Atmospheric Science, Pipes and vents, Gases, Setting up the mix chamber

As an atmospheric technician, your primary job is to maintain a safe and breathable atmosphere inside the station. As a member of the engineering department, you may also be expected to double as a Station Engineer if they don't know what they're doing in exceptional circumstances.

The primary threats to a safe and breathable atmosphere inside the station are:

  • Air escaping into space due to intentional or unintentional removal of walls or floor tiles (spacing)
  • Buildup of unpleasant or outright hazardous gases such as ammonia or plasma

Atmospheric technicians are essential to keeping the station alive and breathing, and consequently are ineligible to be Traitor.


Quick-Start

  1. Grab equipment from your atmospheric technician locker. You should grab at least a hardsuit or fire suit and helmet, a gas mask and gas tank, a gas analyzer, and a holofan projector. Consider grabbing inflatable walls, inflatable doors, steel sheets, and metal rods to be ready to fix spacing.
  2. Find the distro pipe and inspect its pressure and temperature using your gas analyzer. If the pressure is zero and shows no sign of rising, take corrective action.
  3. (optional) Set filters to recover gases from the waste pipe. Because gas miners are available on most stations, this step is not very important. And, unless scrubbers are set to siphoning, there will only be waste gases in the waste pipe.
  4. Deliver portable scrubbers to locations that expect miasma build up. This is usually the cloning room or morgue in the medical bay.
  5. Monitor the station's radio or patrol the station yourself for spacing or other atmospheric issues. Fix issues if they arise.
  6. Make sure that suspicious people are not sabotaging your department.

Equipment

Like your fellow Station Engineers, you start with a full belt of tools. Atmospheric technicians may also have access to:

Atmospheric Equipment
Picture Name Description
Portable Oxygen Tank Small enough to carry around. Hook this up to a mask, and you can have a portable air supply to breathe while in space or fixing leaks. People will probably ask you for these.
Gas Analyzer Use this to analyze the composition of gases in the air around you, or to measure the temperature and pressure of gases inside pipes.
Portable Scrubber Can be wrenched down to scrub waste gases to an internal tank. Useful for quickly containing gas leaks. Must be emptied once full.
Holofan Projector
A holofan projection
Creates a holographic firelock (holofan) that blocks gas flow but allows objects to move through them. Holofans last for three minutes before despawning. Extremely useful when repairing a hull breach, since they will safely block the flow of station atmosphere while still giving access to move around freely to work. Stores a total of six charges before the internal Power cell runs out of power.

Atmosia

Main article: Atmospheric Science

Atmospherics, sometimes referred to as Atmosia, is where most of the station's air handling machinery is located. Each station has a different atmospherics layout. While seasoned atmospheric technicians may have atmospheric layouts memorized, frequent useless station remodeling station engineering changes mean that it is more important to be able to quickly understand the layout of the station that you're currently working on.

Gases

Main article: Gases

Pipes and Machinery

Main article: Pipes and vents

Pressure and moles

All gas can be quantified by its pressure, mole amount, and temperature. These three variables are closely related and directly affect one another. If you add more gas(# of moles) to a given area, the pressure will increase. Take the same amount of moles and lower the volume by using a smaller room and the pressure will be even larger. If you then heat up the gas, the pressure will be even larger still. The opposite is also true, less gas means lower pressure. cooling down gas will also lower the pressure. Volume, or size of the room, also plays a role in pressure. A larger area will require more gas while a smaller area will require less gas to reach the same pressure. using this knowledge we can see why space has a low pressure because the area and temperature are so low.

Moles are a way of measuring how much gas is present in a given area. A higher pressure does not always mean more of a gas in the given area. If you want to physically fit a larger amount of a gas in a specific area, you will need to cool the gas down to lower the temperature, thus lowering the pressure allowing more moles to fit inside the given area.

If you open a canister will 100 moles of air into a large hallway, you will hardly notice a difference in pressure. However, if you open the same tank in a small room the pressure difference will be greater.

The standard livable air requirements are about 20 moles of oxygen and 80 moles of nitrogen at a pressure of 101kpa and temperature of 20° Celsius. If you have less than 20 moles of oxygen present, your character will begin to gasp and take oxygen deprivation damage. If the pressure is any lower or higher than 101kpa, your character will begin to take brute damage in relation to the depressurization or overpressurization levels. If the temperature is much lower or higher than 20°C, you risk your character taking burn damage from the extreme cold or heat.

Generally speaking:

  • More gas(# of moles) = more pressure.
  • Less gas(# of moles) = less pressure.
  • Hot gas = more pressure.
  • Cold gas = less pressure.
  • Large hallway = more moles/higher temperatures needed to notice pressure change.
  • Small hallway = less moles/higher temperatures needed to notice pressure change.

Air Alarms

Air Alarms can be found all over the station in form of panels. They connect and manage active vents, scrubbers, air sensors and firelocks together. They have 3 possible states: Normal, Warning and Alarm. Warning indicates possible build-up of dangerous gases or other issues with the atmosphere that aren't directly lethal. The Alarm state it will close all firelocks connected to that panel, indicating a possibly lethal threat, like a spacing.

At the bottom of the panel there is a mode selector. You can select between:

  • Filtering - Normal filtering, removes all gases except Nitrogen and Oxygen.
  • Filtering (wide) - Enables WideNet which also filters tiles adjacent to a scrubber.
  • Fill - Turns off the scrubbers and fills the room through the vents.
  • Panic - Sucks out all gases and turns off the vents.

You can view the atmosphere composition on the tile a sensor is located by using the Sensors tab, which gives you detailed insights about the gases, pressure and temperature.

Dealing with gas leaks

Gas leaks are a random even that occurs on the station. They can be usually quickly located by reports on the radio and firelocks going off. Most gases aren't directly harmful and are filtered off by the scrubbers network, but Tritium, Plasma or Frezon need to be quickly removed using Portable Scrubbers, usually found in the Atmos area of the Engineering department.

The most effective way of containing extreme pressures and temperatures (like these caused by plasma fires) is spacing the room, which can be done using an RCD or a fire axe.

Space wind

Explosive decompression, or space wind, is caused when a sudden low pressure or depressurization zone occurs and all the atmosphere flows from high pressure to low pressure. Space wind often happens due to a sudden hull breach or when the clown opens the external airlock. All personnel and lose objects in the area will be flung toward the low pressure area as if a gust of wind blows you towards the breach site, thus the name 'Space Wind' is dubbed.

Space wind is very deadly to any crew member not wearing hardsuits with internals. Space wind will often suck you far away from safety and toward the breach site. The damage you take from slamming into objects (and objects slamming into you) along with depressurization, lack of oxygen, and freezing temperatures will often quickly kill any unsuspecting crewmember who gets caught.

Useful trivia and tricks

  • Always be prepared to fix a breach. Carry your Atmospherics hardsuit or firesuit with you so you can survive long enough to fix any breach at a moments notice.
  • The Atmospherics firesuit is space proof and functions like a hardsuit. Just make sure you wear the helmet with it or else it wont give you any protection.
  • The standard air mix is 21% oxygen and 79% nitrogen @ 101.325 kPa at 293.15K (20°C).
  • A quick and dirty way to vent high pressure or unwanted gases is to expose the area to open space. Breach a wall or open an airlock to quickly suck out all the atmosphere. Just be sure you have the area sealed off and no crewmembers get caught in the depressurization zone!
  • Overpressurization can be just as harmful as depressurization!
  • A pressurized pipe will violently decompress if unwrenched!
  • If you want to check the pressure and temperature of a pipe, hold your gas analyzer in hand and left-click on the pipe.
  • Make sure that the distro loop never connects to anything else like the mix or waste loop. unless you want to flood the station with superheated plasma and risk getting an angry admin message.
Roles on DeltaV
Command Captain · Head of Personnel · Head of Security · Chief Engineer · Mystagogue · Chief Medical Officer · Logistics Officer · Chief Justice
Justice Department Chief Justice · Clerk · Prosecutor · Lawyer
Security Head of Security · Warden · Security Officer · Prison Guard · Corpsman · Detective · Security Cadet
Engineering Chief Engineer · Atmospheric Technician · Station Engineer · Technical Assistant
Epistemics Mystagogue · Psionic Mantis · Chaplain · Scientist · Research Assistant
Medical Chief Medical Officer · Medical Doctor · Paramedic · Chemist · Psychologist · Medical Intern
Logistics Logistics Officer · Cargo Technician · Salvage Specialist · Courier
Service Head of Personnel · Janitor · Bartender · Botanist · Chef · Service Worker · Boxer · Clown · Martial Artist · Mime · Musician · Reporter · Passenger · Zookeeper · Librarian · Gladiator · Prisoner
Sillicon Cyborg · Personal AI
Antagonists Traitor · Nuclear Operative · Space Ninja · Thief · Paradox Anomaly · Revenant · Space Dragon · Listening Post Operative · Zombie